Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Oncol ; 17(1): 76, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35428265

RESUMEN

BACKGROUND: The irradiation of breast cancer patients with included internal mammary lymph nodes challenges radiation planning with regard to robustness and protection of OARs. In this publication, a feasible hybrid radiation technique is presented with a retrospective dosimetric and radiobiological analysis of patient data of our institute from 2016 to 2020 and robustness analysis. METHODS: The proposed hybrid irradiation technique consists of two IMRT tangents and two partial VMAT fields. The retrospective dosimetric and radiobiological evaluation are made for 217 patient treatments (right- and left-sided). The robustness is evaluated regarding an artificial swelling from 0.4 to 1.5 cm for a random example patient and compared to a pure VMAT planning technique with use of a virtual bolus. The out of field stray dose is calculated for a selected patient plan and compared to alternative radiation techniques. RESULTS: The coverage D95% of the PTVEval (with breast swelling of 1.5 cm) changes for the hybrid plan from 96.1 to 92.1% of prescribed dose and for the pure VMAT plan from 94.3 to 87%. The retrospective dosimetric evaluation of patient irradiations reveals a Dmean for total lung 6.5 ± 0.9 Gy (NTCP[Semenenko 2008] 2.8 ± 0.5%), ipsilateral lung 10.9 ± 1.5 Gy, contralateral lung 2.2 ± 0.6 Gy, heart 2.1 ± 1.1 Gy (ERR[Schneider 2017] 0.02 ± 0.17%) and contralateral breast 1.7 ± 0.6 Gy. The scatter dose of the hybrid irradiation technique is higher than for pure VMAT and lower than for pure IMRT irradiation. CONCLUSIONS: The feasibility of the proposed planning technique is shown by treating many patients with this technique at our radiotherapy department. The hybrid radiation technique shows a good sparing of the OARs in the retrospective analysis and is robust with regards to a breast swelling of up to 1.5 cm. The slightly higher stray dose of the hybrid technique compared to a pure VMAT technique originates from higher number of MUs and lower conformity.


Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Neoplasias de la Mama/radioterapia , Femenino , Humanos , Ganglios Linfáticos , Órganos en Riesgo/efectos de la radiación , Técnicas de Planificación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...